Search results for "frequency [modulation]"

showing 10 items of 569 documents

Design and Implementation of Acoustic Source Localization on a Low-Cost IoT Edge Platform

2020

The implementation of algorithms for acoustic source localization on edge platforms for the Internet of Things (IoT) is gaining momentum. Applications based on acoustic monitoring can greatly benefit from efficient implementations of such algorithms, enabling novel services for smart homes and buildings or ambient-assisted living. In this context, this brief proposes extreme low-cost sound source localization system composed of two microphones and the low power microcontroller module ESP32. A Direction-Of-Arrival (DOA) algorithm has been implemented taking into account the specific features of this board, showing excellent performance despite the memory constraints imposed by the platform. …

business.industryMicrophoneComputer scienceEmbedded systemsProcess (computing)Esp32Context (language use)Acoustic source localizationIngeniería IndustrialTime–frequency analysisSound source localizationMicrocontrollerDoa estimationEnhanced Data Rates for GSM EvolutionElectrical and Electronic EngineeringbusinessImplementationComputer hardware
researchProduct

Internet banking loyalty: evaluating the role of trust, satisfaction, perceived risk and frequency of use

2011

This paper analyses the role of satisfaction, trust, frequency of use and perceived risk as antecedents of consumer loyalty to banking websites. While the literature usually focuses on the direct effects of these variables, special attention is paid here to evaluate their moderating effects on the relationship between satisfaction and loyalty. The results from a sample of 254 Spanish users of Internet banking services show that while satisfaction correlates positively with loyalty, the effect is significantly less intense with high levels of perceived risk. The results are similar for trust, which correlates more positively with high levels of perceived risk, but also when Internet banking …

business.industryStrategy and Managementmedia_common.quotation_subjectConsumer loyaltyDirect effectsFrequency of useSample (statistics)Risk perceptionManagement of Technology and InnovationLoyaltyThe InternetMarketingbusinessPsychologymedia_commonThe Service Industries Journal
researchProduct

Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants

2014

Background To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. Purpose This retrospective study aimed to assess the suitability of three stability parameters – namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values – as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Materials and Methods Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediatel…

business.industrymedicine.medical_treatmentArea under the curveDentistryAnatomyImplant stability quotientOsseointegrationResonance frequency analysisMaxillaImmediate loadingmedicineImplantOral SurgeryDenturesbusinessGeneral DentistryClinical Implant Dentistry and Related Research
researchProduct

Updated secondary implant stability data of two dental implant systems. A retrospective cohort study

2017

Background At present, updated secondary implant stability data generated by actual versions of resonance frequency analysis (RFA) and mobility measurement (MM) electronic devices of 2 different implant systems with actual manufactured surfaces seem to lack and/or are incomplete. Material and Methods Secondary implant stability data based on both RFA and MM measurements were collected and analyzed from 44 formerly treated patients (24 f, 20 m) that received either Ankylos Cellplus (Ø3.5mm) (A) (n=36) or Straumann regular neck SLA tissue level (Ø4.1mm) (S) (n=37) implants in posterior positions of both jawbones (total number= 72). These results were interpretated in view of formerly publishe…

business.industrymedicine.medical_treatmentResearchTissue levelDentistryRetrospective cohort study:CIENCIAS MÉDICAS [UNESCO]First generationResonance frequency analysisUNESCO::CIENCIAS MÉDICASMedicinePeriodontologyImplantbusinessDental implantGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct

High-contrast sub-Doppler absorption spikes in a hot atomic vapor cell exposed to a dual-frequency laser field

2017

International audience; The saturated absorption technique is an elegant method widely used in atomic and molecular physics for high-resolution spectroscopy, laser frequency standards and metrology purposes. We have recently discovered that a saturated absorption scheme with a dual-frequency laser can lead to a significant sign reversal of the usual Doppler-free dip, yielding a deep enhanced-absorption spike. In this paper, we report detailed experimental investigations of this phenomenon, together with a full in-depth theoretical description. It is shown that several physical effects can support or oppose the formation of the high-contrast central spike in the absorption profile. The physi…

coherent population trappingGeneral Physics and Astronomy01 natural scienceslaw.invention010309 opticssymbols.namesakelawLaser cooling0103 physical sciencesvapor cellPhysics::Atomic Physics010306 general physicsAbsorption (electromagnetic radiation)Spectroscopyoptical pumpingPhysicsQuantum optics[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]Doppler-free spectroscopydual-frequency laserLaserAtomic clockMetrologyHanle effectsymbolsAtomic physics[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]Doppler effect
researchProduct

Shift-Invariant Canonical Polyadic Decomposition of Complex-Valued Multi-Subject fMRI Data with a Phase Sparsity Constraint

2020

Canonical polyadic decomposition (CPD) of multi-subject complex-valued fMRI data can be used to provide spatially and temporally shared components among groups with both magnitude and phase information. However, the CPD model is not well formulated due to the large subject variability in the spatial and temporal modalities, as well as the high noise level in complex-valued fMRI data. Considering that the shift-invariant CPD can model temporal variability across subjects, we propose to further impose a phase sparsity constraint on the shared spatial maps to denoise the complex-valued components and to model the inter-subject spatial variability as well. More precisely, subject-specific time …

complex-valued fMRI dataComputer sciencespatiotemporal constraintscomputer.software_genrecanonical polyadic decomposition (CPD)030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinetoiminnallinen magneettikuvausVoxelshift-invariantImage Processing Computer-AssistedmedicineHumansTensorElectrical and Electronic EngineeringInvariant (mathematics)Radiological and Ultrasound Technologymedicine.diagnostic_testsignaalinkäsittelyBrainComplex valuedsignaalianalyysiSignal Processing Computer-Assistedsource phase sparsityMagnetic Resonance ImagingComputer Science ApplicationsNorm (mathematics)Frequency domainSpatial variabilityFunctional magnetic resonance imagingAlgorithmcomputerAlgorithmsSoftware
researchProduct

Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, osseodensification: an in vitro study

2020

Background Primary stability is an important key determinant of implant osseointegration. We investigated approaches to improve primary implant stability using a new drilling technique termed osseodensification (OD), which was compared with the conventional under-drilling (UD) method utilized for low-density bones. Material and Methods We placed 55 conical internal connection implants in each group, in 30 low-density sections of pig tibia. The implants were placed using twist drill bits in both groups; groups Under Drilling (UD) and Osseodensification (OD) included bone sections subjected to conventional UD and OD drilling, respectively. Before placing the implants, we randomized the bone s…

computer-assisted diagnosisMaterials scienceSwinecomputer-assisted image processingOsseointegrationDental Prosthesis Retentionradicular cysts03 medical and health sciences0302 clinical medicineBone DensityOsseointegrationLow densityAnimalscomputer-assisted image analysisIn vitro studyTibiaGeneral DentistryUNESCO:CIENCIAS MÉDICASInternal connectionDental ImplantsResearchTwist drillDental Implantation EndosseousResonance Frequency Analysis030206 dentistryResonance frequency analysisTorqueOtorhinolaryngologykeratocystsodontogenic cystsSurgeryImplantImplantologyBiomedical engineering
researchProduct

Effects of electrical stimulation pattern on quadriceps isometric force and fatigue in individuals with spinal cord injury

2015

Introduction Variable frequency trains (VFT) or train combinations have been suggested as useful strategies to offset the rapid fatigue induced by constant frequency trains (CFT) during electrical stimulation. However, most studies have been of short duration with limited functional application in those with spinal cord injury (SCI). We therefore tested force and fatigue in response to VFT, CFT, and combined patterns in strength training-like conditions (6-s contractions). Methods Ten SCI individuals underwent either CFT or VFT patterns until target torque was no longer produced and then switched immediately to the other pattern. Results Target torque was reached more times when VFT was use…

contractionsmedicine.medical_specialtyhuman skeletal-muscleStimulationIsometric exercisefunctional electrical stimulationPhysical medicine and rehabilitationMuscle nervemedicinecatch-like propertyOrthopedics and Sports MedicinemovementsShort durationSpinal cord injuryconstant frequency trainsmechanismsexercisebusiness.industrysummationRehabilitationmedicine.diseaseFESfrequency[ SDV.NEU ] Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]Constant frequencymuscle fatigueelectromyostimulationbusinessstrengthvariable frequency trains
researchProduct

Non-linear optical, electrochemical and spectroelectrochemical properties of amphiphilic inner salt porphyrinic systems

2016

Three zwitterionic meso-substituted A3B- and AB2C-porphyrins containing one sulfonato alkylpyridinium substituent and three or two alkoxy-substituted phenyl groups were synthesized in good yield and fully characterized as to their physicochemical properties by a variety of techniques. This new series of inner salt donor-acceptor meso-substituted porphyrin derivatives were prepared for possible application as amphiphilic probes for membrane insertion in the area of combined second-harmonic and two-photon fluorescence cellular microscopy. To this end, the linear and nonlinear optical properties of the compounds were characterized, together with their electrochemical and spectroelectrochemica…

designInorganic chemistrySubstituentamphiphilic inner salt02 engineering and technology010402 general chemistryElectrochemistryPhotochemistry[ CHIM ] Chemical Scienceselectron-accepting moieties01 natural sciencesnon-linear optical propertychemistry.chemical_compoundAmphiphilechromophores[CHIM]Chemical SciencesMoleculeChemistryfrequency dispersionSecond-harmonic generationspectroelectrochemistrydipolar complexesGeneral Chemistry021001 nanoscience & nanotechnologyPorphyrinFluorescence0104 chemical sciences2nd-harmonic generationelectrochemistrymicroscopycharge-transferfluorescenceAbsorption (chemistry)hyper-rayleigh scattering0210 nano-technologyJournal of Porphyrins and Phthalocyanines
researchProduct

Time-Frequency Characteristics of In-Home Radio Channels Influenced by Activities of the Home Occupant

2019

While aging is a serious global concern, in-home healthcare monitoring solutions are limited to context-aware systems and wearable sensors, which may easily be forgotten or ignored for privacy and comfort reasons. An emerging non-wearable fall detection approach is based on processing radio waves reflected off the body, who has no active interaction with the system. This paper reports on an indoor radio channel measurement campaign at 5.9 GHz, which has been conducted to study the impact of fall incidents and some daily life activities on the temporal and spectral properties of the indoor channel under both line-of-sight (LOS) and obstructed-LOS (OLOS) propagation conditions. The time-frequ…

device-free fall detectionComputer scienceReal-time computingWearable computerVDP::Information and communication science: 42002 engineering and technologylcsh:Chemical technology01 natural sciencesBiochemistryArticleAnalytical ChemistryDoppler power spectral density0202 electrical engineering electronic engineering information engineeringlcsh:TP1-1185Electrical and Electronic EngineeringInstrumentationnon-stationary radio channels010401 analytical chemistry020206 networking & telecommunicationsAtomic and Molecular Physics and Optics0104 chemical sciencesTime–frequency analysisspectrogram analysisVDP::Informasjons- og kommunikasjonsvitenskap: 420Radio waveCommunication channelambient-assisted livingSensors (Basel, Switzerland)
researchProduct